Introduction

InfiniBand (IB) is a high-performance, low-latency networking technology originally developed in the late 1990s by the InfiniBand Trade Association (IBTA). Unlike traditional Ethernet, InfiniBand was designed from the ground up for high-performance computing (HPC), storage fabrics, and data center interconnects, offering features like hardware-level remote direct memory access (RDMA), credit-based lossless flow control, and very high bandwidth.

Modern InfiniBand is the interconnect of choice for the world’s fastest supercomputers and AI training clusters. As of 2025, over 60% of the Top500 supercomputers use InfiniBand networking, with speeds reaching 400 Gbps (NDR) and 800 Gbps (XDR).

Key characteristics:

  • Bandwidth: SDR (2.5 Gbps) → DDR (5 Gbps) → QDR (10 Gbps) → FDR (14.0625 Gbps) → EDR (25.78125 Gbps) → HDR (50 Gbps) → NDR (100 Gbps) → XDR (200 Gbps per lane, 800 Gbps aggregate)
  • Latency: Sub-microsecond for small messages
  • RDMA: Native hardware-level remote memory access
  • Lossless: Credit-based flow control — no packet drops under normal operation
  • CPU offload: NIC handles protocol processing without CPU involvement

Architecture Overview

graph TB
    subgraph "InfiniBand Network"
        subgraph "Subnet"
            subgraph "End Nodes"
                HCA1["HCA (Host Channel Adapter)<br>Compute Node 1"]
                HCA2["HCA (Host Channel Adapter)<br>Compute Node 2"]
                HCA3["HCA (Host Channel Adapter)<br>Storage Node"]
            end
            subgraph "Switches"
                SW1["IB Switch<br>(Leaf/Spine)"]
                SW2["IB Switch<br>(Spine)"]
            end
            subgraph "Subnet Management"
                SM["Subnet Manager<br>(OpenSM)"]
                SA["Subnet Administration"]
            end
        end
        subgraph "Router"
            RTR["IB Router<br>(Connects subnets)"]
        end
    end

    HCA1 --> SW1
    HCA2 --> SW1
    HCA3 --> SW2
    SW1 --> SW2
    SM --> SW1
    SM --> SW2
    SA --> SM
    SW2 --> RTR

Components

ComponentDescriptionLinux Representation
HCA (Host Channel Adapter)Network interface card for IBmlx5_0, mlx4_0
SwitchForwards IB packets (LID-based routing)Managed via SM
Subnet Manager (SM)Configures routing, assigns LIDs, manages topologyOpenSM / ib_sm
Subnet Administration (SA)Provides information about subnet topologysaquery tool
RouterConnects IB subnetsib_routing

InfiniBand Packet Structure

InfiniBand uses Transport Layer Packets (TLPs) with a link-layer header:

┌──────────────┬──────────────┬─────────────┬───────────┬──────────┐
│ Local Route  │ Global Route │   Base      │  Payload  │  ICRC    │
│ Header (LRH) │ Header (GRH) │ Transport   │  (0-4096  │ (32-bit  │
│  (8 bytes)   │ (40 bytes)   │ Header (BTH)│   bytes)  │  CRC)    │
│              │  (optional)  │  (12 bytes) │           │          │
└──────────────┴──────────────┴─────────────┴───────────┴──────────┘
  • LRH: Contains SLID (Source LID), DLID (Destination LID), Virtual Lane (VL)
  • GRH: Used for L3 routing between subnets (IPv6-based GID addressing)
  • BTH: Opcode, destination QP, PSN (Packet Sequence Number)

Speed Evolution

GenerationSpeed (4x)EncodingLink RateYearIBTA Spec
SDR10 Gbps8b/10b2.5 Gbps20011.0
DDR20 Gbps8b/10b5 Gbps20041.1
QDR40 Gbps8b/10b10 Gbps20071.2
FDR56.25 Gbps64b/66b14.0625 Gbps20111.3
EDR100 Gbps64b/66b25.78125 Gbps20141.4
HDR200 GbpsPAM450 Gbps20191.5
NDR400 GbpsPAM4100 Gbps20221.6
XDR800 GbpsPAM4200 Gbps2025+1.7

Topology Types

Fat Tree

Common in HPC clusters — non-blocking bisection bandwidth:

graph TB
    subgraph "Spine Layer"
        S1["Spine Switch 1"]
        S2["Spine Switch 2"]
    end
    subgraph "Leaf Layer"
        L1["Leaf Switch 1"]
        L2["Leaf Switch 2"]
        L3["Leaf Switch 3"]
        L4["Leaf Switch 4"]
    end
    subgraph "Compute Nodes"
        N1["Node 1"]
        N2["Node 2"]
        N3["Node 3"]
        N4["Node 4"]
    end

    L1 --> S1
    L1 --> S2
    L2 --> S1
    L2 --> S2
    L3 --> S1
    L3 --> S2
    L4 --> S1
    L4 --> S2
    N1 --> L1
    N2 --> L1
    N3 --> L2
    N4 --> L2

Torus/Mesh

Used in large-scale HPC for direct-connect topologies:

graph LR
    N1["Node 1"] --- N2["Node 2"]
    N2 --- N3["Node 3"]
    N3 --- N4["Node 4"]
    N4 --- N1
    N1 --- N3
    N2 --- N4

Linux InfiniBand Stack

Kernel Modules

graph TB
    subgraph "User Space"
        VERBS_APP["Application (libibverbs)"]
        RDMA_CM["rdma_cm (Connection Manager)"]
        IBV["libibverbs (Verbs API)"]
    end
    subgraph "Kernel"
        IB_CORE["IB Core<br>drivers/infiniband/core/"]
        RDMA_SUB["RDMA Subsystem<br>drivers/rdma/"]
        subgraph "Hardware Drivers"
            MLX5["mlx5_ib (ConnectX-4/5/6/7)"]
            MLX4["mlx4_ib (ConnectX-3)"]
            BNXT_RE["bnxt_re (Broadcom)"]
            EFA["efa (AWS)"]
            HFI1["hfi1 (Intel OPA)"]
            QIB["qib (QLogic IB)"]
        end
        subgraph "Upper Layer Protocols"
            SRP["ib_srpt (SCSI RDMA)"]
            ISER["ib_iser (iSCSI RDMA)"]
            NFSRDMA["svcrdma / rpcrdma (NFS)"]
            RDS["rds (Reliable Datagram)"]
        end
    end
    subgraph "Hardware"
        HCA["HCA / RNIC"]
    end

    VERBS_APP --> IBV
    RDMA_CM --> IBV
    IBV --> IB_CORE
    IB_CORE --> RDMA_SUB
    RDMA_SUB --> MLX5
    RDMA_SUB --> MLX4
    RDMA_SUB --> BNXT_RE
    RDMA_SUB --> EFA
    RDMA_SUB --> HFI1
    RDMA_SUB --> QIB
    MLX5 --> HCA
    SRP --> IB_CORE
    ISER --> IB_CORE
    NFSRDMA --> IB_CORE
    RDS --> IB_CORE

Key Kernel Files

PathPurpose
drivers/infiniband/core/IB core: verbs, CM, MAD, SA
drivers/infiniband/core/ib_core.cCore initialization
drivers/infiniband/core/uverbs_main.cUserspace verbs (/dev/infiniband/uverbs*)
drivers/infiniband/core/cma.cRDMA Connection Manager
drivers/infiniband/core/mad.cManagement Datagram handling
drivers/infiniband/hw/mlx5/Mellanox ConnectX driver
include/rdma/ib_verbs.hCore verbs header
include/uapi/rdma/Userspace API headers

Hardware: Host Channel Adapters (HCAs)

NVIDIA (Mellanox) ConnectX Series

HCASpeedIB GenKey Features
ConnectX-340 GbpsQDR/FDRLegacy, still deployed
ConnectX-4100 GbpsEDRSR-IOV, VXLAN offload
ConnectX-5100 GbpsEDRNVMe offload, enhanced VXLAN
ConnectX-6200 GbpsHDRCrypto offload, multi-host
ConnectX-6 Dx200 GbpsHDRIPsec/TLS offload
ConnectX-7400 GbpsNDRGPUDirect, SHARP
ConnectX-8800 GbpsXDRLatest generation

Intel Omni-Path (OPA)

Intel’s alternative IB-compatible fabric (HFI1 driver):

  • 100 Gbps per port
  • Integrated in Intel Xeon processors (some models)
  • Uses hfi1 kernel driver

Configuration

Installing InfiniBand Packages

# Debian/Ubuntu
sudo apt install rdma-core ibverbs-utils infiniband-diags \
    opensm perftest rdmacm-utils ibutils

# RHEL/CentOS/Fedora
sudo dnf install rdma-core libibverbs-utils infiniband-diags \
    opensm perftest librdmacm-utils

# NVIDIA MLNX_OFED (recommended for latest features)
# Download from: https://network.nvidia.com/products/infiniband-drivers/linux/mlnx_ofed/
sudo ./mlnxofedinstall --add-kernel-support --without-fw-update

Loading Kernel Modules

# Core IB modules
sudo modprobe ib_core
sudo modprobe ib_uverbs
sudo modprobe ib_umad
sudo modprobe ib_cm
sudo modprobe iw_cm
sudo modprobe rdma_cm
sudo modprobe rdma_ucm

# Mellanox drivers
sudo modprobe mlx5_core
sudo modprobe mlx5_ib

# Legacy Mellanox
sudo modprobe mlx4_core
sudo modprobe mlx4_ib

# Verify
lsmod | grep -E "ib_|mlx|rdma"

Verifying HCA Status

# List IB devices
$ ibv_devices
    device           node GUID
    ------           ----------------
    mlx5_0           0002c90300abcdef

# Detailed device info
$ ibv_devinfo -d mlx5_0
hca_id: mlx5_0
        transport:                      InfiniBand (0)
        fw_ver:                         16.35.2000
        node_guid:                      0002c903:00abcdef
        sys_image_guid:                 0002c903:00abcdef
        vendor_id:                      0x02c9
        vendor_part_id:                 4119
        hw_ver:                         0x0
        phys_port_cnt:                  1
        port:   1
                state:                  PORT_ACTIVE (4)
                max_mtu:                4096 (5)
                active_mtu:             4096 (5)
                sm_lid:                 1
                port_lid:               3
                port_lmc:               0x00
                link_layer:             InfiniBand

# IB port status
$ ibstat mlx5_0
CA 'mlx5_0'
        CA type: MT4119
        Num ports: 1
        Firmware version: 16.35.2000
        Hardware version: 0
        Node GUID: 0x0002c90300abcdef
        System image GUID: 0x0002c90300abcdef
        Port 1:
                State: Active
                Physical state: LinkUp
                Rate: 100
                Base lid: 3
                LMC: 0
                SM lid: 1
                Capability mask: 0x2651e848
                Port GUID: 0x0002c90300abcdef
                Link layer: InfiniBand

Subnet Manager (OpenSM)

The Subnet Manager (SM) is essential for InfiniBand operation. It discovers the fabric topology, assigns Local IDs (LIDs) to each port, computes routing tables, and configures switches.

OpenSM Basics

# OpenSM is the reference open-source Subnet Manager
# Install
sudo apt install opensm    # Debian/Ubuntu
sudo dnf install opensm    # RHEL/Fedora

# Start OpenSM (typically runs on one node or on a switch)
sudo opensm

# Or as a systemd service
sudo systemctl enable opensm
sudo systemctl start opensm

# Run on a specific port
sudo opensm -g 0x0002c90300abcdef    # By GUID
sudo opensm -B    # Run in background (daemon mode)

# Specify a partition configuration file
sudo opensm -P /etc/opensm/partitions.conf

OpenSM Routing Engines

# Default routing: MinHop (shortest path)
sudo opensm -R minhop

# Fat-tree optimized routing
sudo opensm -R ftree

# Up/Down routing (avoids routing loops)
sudo opensm -UP

# LASH (Linear Assignment for Source-based Hop-by-hop routing)
sudo opensm -R lash

# Torus-2QoS (for torus topologies)
sudo opensm -R torus-2QoS

# Dragonfly routing
sudo opensm -R dfsssp

Partition Configuration

# /etc/opensm/partitions.conf
# Default partition (all ports)
Default=0x7fff, ipoib, rate=15:ALL;

# Restricted partition (specific ports only)
Restricted=0x8001, rate=15, mtu=4:0x1234,0x5678,0x9abc;

# Partition with QoS
HighPerf=0x8002, rate=30, mtu=5, sl=3:0xdef0,0x1111;

Fabric Discovery and Monitoring

# Discover fabric topology
ibnetdiscover
# Output shows nodes, ports, and links

# Query node info
ibstat
ibstatus

# Check SM state
smpquery -C mlx5_0 nodeinfo 1    # Port 1
smpquery -C mlx5_0 portinfo 1

# Query SA (Subnet Administration)
saquery                          # List all path records
saquery -c                       # Class Port Info
saquery --smkey 0x1              # SM info

# Get LID-to-GUID mapping
ibaddr

# Port counters (errors, packets)
perfquery -C mlx5_0 -a -x

# Per-port extended counters
perfquery -C mlx5_0 1 -x
# PortXmitData, PortRcvData, PortXmitPkts, PortRcvPkts
# PortXmitDiscards, PortRcvErrors, PortXmitWait

Fabric Topology and Diagnostics

ibnetdiscover

# Discover and display fabric topology
$ ibnetdiscover
# Output:
# vendid=0x2c9
# devid=0xcb84
# sysimgguid=0x0002c90300abcdef
# switchguid=0x0002c90300abcdef(0002c90300abcdef)
# Switch  36 "S-0002c90300abcdef"     # "Switch Mellanox" lid 1 lmc 0
#     1  "H-0002c90300abcdef"        # "Node 1 mlx5_0" lid 3
#     2  "H-0002c90300abcdef"        # "Node 2 mlx5_0" lid 4
# CA    40 "H-0002c90300abcdef"
#     1  "S-0002c90300abcdef"        # lid 3 lmc 0 "mlx5_0"

# Generate topology file for analysis
ibnetdiscover > /tmp/ibnet.topology

# Graphical topology (needs graphviz)
ibtopo2dot /tmp/ibnet.topology > /tmp/ibtopo.dot
dot -Tpng /tmp/ibtopo.dot -o /tmp/ibtopo.png

ibdiagnet (Fabric Diagnostics)

# Comprehensive fabric diagnostics
$ ibdiagnet
# Performs:
# - Topology discovery
# - LID assignment verification
# - Link quality checks
# - Error counter analysis
# - Routing verification

# Output:
# Loading IBDiagnet...
# -I- Discovering ... 2 nodes found
# -I- Topology is OK
# -I- Errors       : 0
# -I- Warnings     : 0

# Additional options
ibdiagnet -r           # Record topology to file
ibdiagnet --skip dup_guids  # Skip duplicate GUID checks
ibdiagnet -P all=0xff  # Check all ports

ibping (Connectivity Test)

# IB ping — tests L2 connectivity
# Server side:
ibping -S    # Start as server

# Client side:
ibping -L 3    # Ping node with LID 3

# Ping by GUID
ibping -G 0x0002c90300abcdef

ibtracert (Route Tracing)

# Trace path between two endpoints
ibtracert 3 4    # From LID 3 to LID 4

# Shows each hop:
# From ca lid 3 port 1 to ca lid 4 port 1
# Hop 1: Switch lid 1 out port 1 -> in port 2
# Hop 2: ca lid 4 port 1

Performance Benchmarking

# RDMA Write bandwidth (IB transport)
# Server:
ib_write_bw -d mlx5_0 -a
# Client:
ib_write_bw -d mlx5_0 --report_gbits 192.168.100.2

# RDMA Read bandwidth
ib_read_bw -d mlx5_0 -a
ib_read_bw -d mlx5_0 --report_gbits 192.168.100.2

# RDMA Write latency
ib_write_lat -d mlx5_0 -a
ib_write_lat -d mlx5_0 192.168.100.2

# Send/Receive latency
ib_send_lat -d mlx5_0 -a
ib_send_lat -d mlx5_0 192.168.100.2

# Bidirectional bandwidth
ib_write_bw -d mlx5_0 -a --bidir
ib_write_bw -d mlx5_0 --bidir --report_gbits 192.168.100.2

# Multi-stream bandwidth
ib_write_bw -d mlx5_0 -a -q 8    # 8 queue pairs
ib_write_bw -d mlx5_0 -q 8 --report_gbits 192.168.100.2

# Atomic latency
ib_atomic_lat -d mlx5_0 -a
ib_atomic_lat -d mlx5_0 192.168.100.2

Typical Performance Numbers

OperationEDR (100G)HDR (200G)NDR (400G)
RDMA Write BW~97 Gbps~195 Gbps~390 Gbps
RDMA Write Lat~1.0 μs~0.8 μs~0.6 μs
RDMA Read Lat~1.5 μs~1.2 μs~0.9 μs
Send Lat~1.2 μs~1.0 μs~0.7 μs

Topology and Routing

Fat-Tree Routing

Fat-tree is the most common topology for IB clusters:

# Configure OpenSM for fat-tree routing
sudo opensm -R ftree -f /var/log/opensm/opensm.log

# Fat-tree requirements:
# - All switches at same level have same number of ports
# - Each switch connects to all switches in adjacent level
# - Non-blocking bisection bandwidth

Topology File Format

# OpenSM topology file (.topology)
# Define node types and connections

# Example topology:
# Switch  1  "Spine-1"    # LID 1
#   1    "Leaf-1"        # connects to port 1
#   2    "Leaf-2"
#   3    "Leaf-3"
#
# Switch  2  "Leaf-1"     # LID 2
#   1    "Spine-1"
#   2    "Spine-2"
#   3    "Compute-1"
#   4    "Compute-2"

InfiniBand in Linux Containers and VMs

SR-IOV for InfiniBand

# Enable SR-IOV on HCA
sudo mlxconfig -d mlx5_0 set SRIOV_EN=1 NUM_OF_VFS=8

# Create VFs
echo 8 | sudo tee /sys/class/infiniband/mlx5_0/device/sriov_numvfs

# List VFs
ls /sys/class/infiniband/

# Assign VF to container
sudo docker run --device /dev/infiniband/uverbs0 \
    --device /dev/infiniband/ucm0 \
    -v /sys/class/infiniband:/sys/class/infiniband \
    ib-app:latest

# Assign VF to VM (libvirt XML)
# <hostdev mode='subsystem' type='pci'>
#   <source>
#     <address domain='0x0000' bus='0x03' slot='0x00' function='0x1'/>
#   </source>
# </hostdev>

Kubernetes RDMA Device Plugin

# Install Mellanox Network Operator for Kubernetes
# This handles RDMA device plugin, SR-IOV, and device management
helm install nic-operator mellanox/network-operator

# Pod spec requesting RDMA resources:
# resources:
#   limits:
#     rdma/hca: 1

Security

Partition Keys (P_Keys)

InfiniBand uses Partition Keys (P_Keys) for fabric-level traffic isolation:

# View P_Key configuration
smpquery -C mlx5_0 pkeytable 1

# P_Key 0x7fff = full partition (default, all members)
# P_Key 0x8000+ = limited membership (can only communicate with full members)

# Configure P_Key in OpenSM partitions.conf
# MyPartition=0x8001, rate=15:0x1234,0x5678;

Service Levels and QoS

# InfiniBand supports 16 Virtual Lanes (VLs)
# VL 0-15, where VL 15 is reserved for management

# Check VL configuration
smpquery -C mlx5_0 portinfo 1 | grep -i vl

# OpenSM QoS configuration
# /etc/opensm/opensm.conf
# qos TRUE
# qos_max_vls 8

Monitoring

# Real-time port counters
watch -n 1 "perfquery -C mlx5_0 -a -x"

# Monitor link errors
perfquery -C mlx5_0 1 | grep -E "Error|Discard|Wait"

# Key counters to monitor:
# PortRcvErrors - Receive errors (CRC, etc.)
# PortXmitDiscards - Transmit drops (congestion)
# PortXmitWait - Time spent waiting to transmit
# PortRcvRemotePhysicalErrors - Remote physical errors
# SymbolErrorCounter - Symbol errors (physical layer)

# Network throughput monitoring
ibstat mlx5_0 | grep -i rate

# Topology changes (SM reconfiguration)
dmesg | grep -i "infiniband\|mlx5"

# Monitor SM state
saquery --smkey 0x1

Troubleshooting

Common Issues

No IB devices found:

# Check PCI devices
lspci | grep -i mellanox
lspci | grep -i infiniband

# Load drivers
sudo modprobe mlx5_core mlx5_ib

# Check dmesg
dmesg | grep -i mlx5
dmesg | grep -i infiniband

Port not active:

# Check port state
ibstat mlx5_0
# State should be "Active", Physical state "LinkUp"

# If "Down": check cable/transceiver
ethtool -m mlx5_0

# If "Initializing": SM not running
sudo systemctl status opensm

# Check SM assignment
ibstat | grep "sm lid"

SM not assigning LIDs:

# Check OpenSM is running
ps aux | grep opensm
sudo systemctl status opensm

# Check OpenSM logs
sudo journalctl -u opensm

# Restart OpenSM
sudo systemctl restart opensm

Poor performance:

# Check link rate
ibstat mlx5_0 | grep Rate

# Check for errors
perfquery -C mlx5_0 -a -x | grep -E "Error|Discard"

# Verify MTU
ibstat mlx5_0 | grep -i mtu

# Check congestion
perfquery -C mlx5_0 1 | grep XmitWait

# NUMA alignment
numactl --hardware
# Pin IB IRQs to NUMA-local CPUs
sudo set_irq_affinity.sh mlx5_0

Duplicate LIDs:

# This indicates fabric misconfiguration
ibdiagnet | grep -i "duplicate"

# Restart SM to reassign LIDs
sudo systemctl restart opensm

References