/sys/class/power_supply
| Field | Value |
|---|---|
| Subsystem | power supply class, drivers/power/supply/power_supply_sysfs.c (attribute table, uevent properties); core in power_supply_core.c |
| Config gate | CONFIG_POWER_SUPPLY (obj-$(CONFIG_POWER_SUPPLY) += power_supply.o in drivers/power/supply/Makefile, torvalds/linux master) |
| ABI documentation | Documentation/ABI/testing/sysfs-class-power |
| Since | per-entry Date: lines start May 2007; 13 entries carry KernelVersion: lines (earliest 2.6.35) |
| Live (5.10.134 host) | class directory present, 0 devices (container without battery/AC entries) |
| Ledger ID | SYSC-power_supply |
What it represents
One directory per power supply object: batteries, AC adapters, USB and wireless chargers, fuel gauges. Each device exposes a flat set of property files whose availability mirrors the POWER_SUPPLY_* properties the driver reports. The same properties are exported in the device uevent as POWER_SUPPLY_* variables (worklog 2-b: add_uevent_var in power_supply_sysfs.c), which is what udev and desktop power daemons consume.
Relationship to the device model
/sys/class/power_supply/<supply> is a class symlink view of a device under /sys/devices/... (ACPI battery, platform charger, USB port device). There is no power_supply bus and no char/block device node. The type and scope files let userspace classify the supply without probing drivers.
Attributes
59 What: entries live in Documentation/ABI/testing/sysfs-class-power; counting every path spelled /sys/class/power_supply/... across the ABI tree (including driver-specific files such as sysfs-class-power-max1720x) gives 82, the number the ledger records. The table below is representative.
| Attribute | R/W | Unit/format | Conditional? | Source |
|---|---|---|---|---|
type | RO | Battery, UPS, Mains, USB, Wireless | always | ABI What <supply_name>/type |
manufacturer, model_name | RO | string | driver-dependent | ABI What entries, May 2007 |
serial_number | RO | string | driver-dependent | ABI What entry, January 2008 |
temp | RO | 1/10 degrees Celsius | battery or charger reporting | ABI What temp |
voltage_now | RO (RW on programmable USB) | microvolts | always for batteries | ABI What voltage_now |
current_now | RO (RW on programmable USB) | microamps; negative while discharging | battery or charger reporting | ABI What current_now |
capacity | RO | 0-100 percent | batteries | ABI What capacity |
health | RO | enum string | batteries | ABI What health |
status | RO | enum (Charging, Discharging, Full, …) | driver-dependent | ABI What status (enum text from POWER_SUPPLY_STATUS_TEXT) |
cycle_count | RO | integer | batteries with gauge | ABI What cycle_count |
uevent | RO | POWER_SUPPLY_* key list | always | power_supply_sysfs.c (worklog 2-b) |
Which files exist is decided by each driver: a mains adapter may expose only online and type, a smart battery dozens of charge/discharge and capacity-level files. Driver-specific extensions are documented in their own ABI files (sysfs-class-power-*).
Safety and writes
Reading is safe; this is the data source of upower, acpi, and desktop battery indicators. Writes are rare and driver-gated: the ABI marks current_now/voltage_now writable only when the supply’s online state is programmable (USB VBUS/IBUS control). Charge-control attributes (for example charge behaviour and current limits in driver-specific files) need root and can stop or alter charging; treat them as hardware policy.
References
Documentation/ABI/testing/sysfs-class-power(cached copy; 59 What: entries)drivers/power/supply/power_supply_sysfs.c,drivers/power/supply/Makefile(torvalds/linux master; key blocks summarized in worklog 2-b)- Ledger row SYSC-power_supply (