RAID (Redundant Array of Independent Disks)

Overview

RAID combines multiple physical disks into a single logical unit to improve performance (parallelism), reliability (redundancy), or both. RAID was originally proposed in 1987 by Patterson, Gibson, and Katz at UC Berkeley. The “I” originally stood for “Inexpensive” but is now “Independent.”

RAID Levels

RAID 0 — Striping

Data is split across disks in stripes.

Disk 0: [A0] [A2] [A4] [A6]
Disk 1: [A1] [A3] [A5] [A7]

File A: A0→A1→A2→A3→A4→A5→A6→A7
PropertyValue
Min disks2
Usable capacity100%
Fault toleranceNone (1 disk failure = total loss)
Read performanceExcellent (parallel)
Write performanceExcellent (parallel)

Use case: Temporary data, scratch space, where speed matters more than safety.

RAID 1 — Mirroring

Every block is duplicated on two (or more) disks.

Disk 0: [A0] [A1] [A2] [A3]
Disk 1: [A0] [A1] [A2] [A3]  ← identical copy
PropertyValue
Min disks2
Usable capacity50% (2-way mirror)
Fault tolerance1 disk failure (2-way)
Read performanceGood (read from either)
Write performanceModerate (write to both)

Use case: OS boot disks, critical data.

RAID 5 — Striping with Distributed Parity

Data and parity are striped across all disks. Parity is distributed (not on a single disk).

Disk 0: [D0] [D1] [D4] [P2]
Disk 1: [D2] [P0] [D5] [D6]
Disk 2: [P1] [D3] [P3] [D7]

P0 = D0 ⊕ D2    (parity for stripe 0)
P1 = D0 ⊕ D1    (parity for stripe 1)
P2 = D4 ⊕ D5    (parity for stripe 2)
P3 = D6 ⊕ D7    (parity for stripe 3)
PropertyValue
Min disks3
Usable capacity(n-1)/n
Fault tolerance1 disk failure
Read performanceExcellent
Write performanceModerate (read-modify-write for parity)

Write penalty: Every write requires reading old data + old parity, computing new parity, writing new data + new parity. This is called the RAID-5 write hole (partially addressed by RAID-Z and journaling).

RAID 6 — Double Distributed Parity

Two independent parity calculations (P and Q) using Reed-Solomon codes.

Disk 0: [D0] [D1] [D4] [Q2]
Disk 1: [D2] [P0] [P2] [D6]
Disk 2: [P1] [D3] [D5] [P3]
Disk 3: [Q0] [Q1] [D7] [Q3]

P = XOR parity
Q = Reed-Solomon parity (can recover from 2 failures)
PropertyValue
Min disks4
Usable capacity(n-2)/n
Fault tolerance2 disk failures
Read performanceExcellent
Write performanceSlower than RAID-5 (two parity computations)

RAID 10 — Mirrored Stripes

RAID 1 + RAID 0: Stripe across mirrored pairs.

Mirror 0:           Mirror 1:
Disk 0: [A0][A2]   Disk 2: [A1][A3]
Disk 1: [A0][A2]   Disk 3: [A1][A3]

File A: A0→A1→A2→A3
PropertyValue
Min disks4
Usable capacity50%
Fault tolerance1 disk per mirror pair
Read performanceExcellent
Write performanceGood

Use case: Databases, high-performance applications.

Comparison Table

RAIDMin DisksCapacityFault ToleranceReadWriteUse Case
02100%None★★★★★★Scratch space
1250%1 disk★★★★Boot drives
53(n-1)/n1 disk★★★★★General storage
64(n-2)/n2 disks★★★Archive, backup
10450%1 per pair★★★★★★Databases

Parity Calculation

XOR Parity (RAID 5)

Given data blocks D0, D1, D2:
  Parity P = D0 ⊕ D1 ⊕ D2

Recovery (if D1 is lost):
  D1 = D0 ⊕ D2 ⊕ P

Reed-Solomon (RAID 6)

Uses Galois Field arithmetic to compute two independent parity values (P and Q). Can recover from any 2 disk failures simultaneously.

RAID 5 Write Hole

Problem: During a stripe write, if power is lost after writing new data but before writing new parity, the parity is inconsistent.

Before crash:
  D0=10, D1=20, P = 10⊕20 = 30

Write D0=15:
  Write D0=15  ✓  (committed)
  Write P = 15⊕20 = 35  ✗  (crash!)

After crash:
  D0=15, D1=20, P=30  ← P is wrong!
  If D1 fails, recovery: D1 = 15⊕30 = 17 (WRONG! Should be 20)

Solutions:

  1. RAID-Z (ZFS): Writes full stripes atomically with COW
  2. Battery-backed write cache (BBWC): Completes writes after power restore
  3. Journaling RAID controllers: Log writes before applying
  4. mdadm write-intent bitmap: Tracks in-progress writes

Hardware vs. Software RAID

AspectHardware RAIDSoftware RAID
ControllerDedicated RAID card (LSI, Dell PERC)OS kernel (mdadm, ZFS)
CPU usageOffloaded to controllerUses host CPU
CacheBattery-backed DRAM cacheHost RAM
PerformanceConsistentDepends on CPU load
Cost$200-1000+Free
FlexibilityLimited to controller featuresFull OS features
RecoveryController-dependentStandard tools

Linux Software RAID (mdadm)

# Create RAID 5
mdadm --create /dev/md0 --level=5 --raid-devices=3 /dev/sd{b,c,d}

# Check status
cat /proc/mdstat
mdadm --detail /dev/md0

# Add hot spare
mdadm --add /dev/md0 /dev/sde

# Remove failed disk
mdadm --fail /dev/md0 /dev/sdc
mdadm --remove /dev/md0 /dev/sdc

# Grow RAID (add disk)
mdadm --grow /dev/md0 --raid-devices=4 --add /dev/sde

RAID-Z (ZFS)

ZFS solves the write hole with variable-width stripes and COW:

RAID-Z1 (3 disks):
  Stripe 1: [D0][D1][P0]     ← full stripe, 2 data + 1 parity
  Stripe 2: [D2][P1]         ← partial stripe, 1 data + 1 parity
  Stripe 3: [D3][D4][D5][P2] ← full stripe, 3 data + 1 parity

Key difference: Stripe width varies per write. No partial stripe updates = no write hole.

Nested RAID Levels

LevelDescriptionCapacityFault Tolerance
RAID 01Stripe of mirrors50%1 per mirror
RAID 10Mirror of stripes50%1 per mirror
RAID 50Stripe of RAID 5(n-s)/n1 per RAID-5 set
RAID 60Stripe of RAID 6(n-2s)/n2 per RAID-6 set

Interview Questions

Q1: What is the RAID 5 write hole and how is it solved?

The write hole occurs when a crash happens between writing new data and updating parity, leaving them inconsistent. Solutions: (1) RAID-Z writes full stripes atomically via COW, (2) battery-backed write cache ensures writes complete after power restore, (3) write-intent bitmap tracks in-progress writes for replay.

Q2: When would you choose RAID 10 over RAID 5?

RAID 10 is better for write-heavy workloads (databases) because it doesn’t have the parity calculation overhead. RAID 5 has a write penalty (read-modify-write for every write). RAID 10 also rebuilds faster after a failure (just copy the mirror) vs. RAID 5 (read all disks to reconstruct). RAID 5 is better for capacity (only lose 1/n vs. 50%).

Q3: How does RAID 6 differ from RAID 5 and when is it needed?

RAID 6 uses two independent parity values (P and Q) so it can survive 2 simultaneous disk failures. RAID 5 can only survive 1. RAID 6 is recommended for large arrays (4+ disks) where the probability of a second failure during rebuild is non-trivial. The trade-off is more write overhead and 2 disks of capacity loss.

Q4: What is the difference between hardware and software RAID?

Hardware RAID uses a dedicated controller with its own CPU and cache. Software RAID (mdadm, ZFS) uses the host CPU. Hardware RAID provides consistent performance and battery-backed cache but costs more and locks you into the controller. Software RAID is free, flexible, and can use advanced features (checksums, COW) but uses host resources.

Q5: Why does ZFS’s RAID-Z not have a write hole?

RAID-Z uses COW: writes go to new locations, never overwrite. Full stripes are written atomically within a transaction group. There’s no state where data is updated but parity isn’t, because the entire stripe either exists (committed) or doesn’t (discarded). Additionally, checksums detect any corruption.

Common Mistakes

  • Using RAID 0 for important data — no redundancy
  • Using RAID 5 with large disks — rebuild time increases, second failure risk during rebuild
  • Mixing hardware RAID with ZFS — ZFS needs direct disk access for checksums
  • Thinking RAID replaces backups — RAID protects against disk failure, not deletion, corruption, or disasters
  • Not monitoring RAID health — silent disk failures can compound

Summary

  • RAID combines disks for performance and/or redundancy
  • RAID 0 (striping) for speed, RAID 1 (mirroring) for safety, RAID 5/6 for balance
  • RAID 10 combines mirroring + striping for best of both
  • RAID 5 write hole: parity inconsistency on crash; solved by RAID-Z, BBWC, or journaling
  • Hardware RAID uses dedicated controllers; software RAID uses OS
  • RAID is not a backup — use it with regular backups

Cross-References